Vatech Green CT 2

MSRP: $82,900.00
$71,900.00
(You save $11,000.00 )
Write a Review

Available Configurations:

Green CT2 ver. 16x9

Multi FOV (5x5 / 8x9 / 12x9 / 16x9) & Panoramic

MSRP $82,900

Our Price $71,900

Rapid Ceph (optional) - add $14,000

 

Green CT2 ver. 18x10

Multi FOV (5x5 / 8x9 / 13x10 / 18x10) & Panoramic

MSRP $98,900

Our Price $88,900

Rapid Ceph (optional) - add $14,000

 

ADVANCED 4-IN-1 DIGITAL X-RAY IMAGING SYSTEM

Green CT 2 is an advanced 4-in-1 digital X-ray imaging system that incorporates PANO, CEPH (Optional), CBCT and MODEL Scan.
It provides high quality images with lower radiation by combining imaging processing and accumulated experience in dental imaging from VATECH.
This will improve your diagnostic accuracy with increased treatment planning and patient satisfaction.

MULTI FOV SELECTION

Green CT 2 offers a range of selectable fields of view.
The Multi FOV enables the user to select the optimum FOV Mode and minimizes exposure to areas not in the region of interest.
Select the proper FOV size among 18x10, 16x9, 13x10, 12x9, 8x9 and 5x5 based on a particular diagnostic need.
It covers the full arch region, sinus and left/right TMJ and it suits most oral surgery cases as well as multiple implant surgeries.

GREEN SCAN TIME

The Green CT 2 minimizes motion artifact and enables faster workflow due to its scan time.
It produces superb diagnostic images, which will be a source of pride for any dental practice.
Focusing on the highest quality of patient care, Vatech strives to improve the health and safety of your patients.

LOW DOSE AND HIGH IMAGE QUALITY

What has been developed at Vatech breaks many conventions in dental radiography.
It was always believed that with low radiation comes inferior image quality, which renders it useless in clinical diagnosis.
However, Green CT 2 provides clinically diagnosable X-ray scans at a low X-ray dosage.
With low dose X-ray radiography, achieving clinically diagnosable image quality is the new golden-standard.

EFFECTIVE DOSE DATA
THE ART-V

Metal artifact hinders visualization and naturally reduces diagnostic confidence.
Clear image gives you less stress and more confidence which leads to accurate diagnosis for implant planning.

*ART-V is the new name of VATECH's MAR function. (Artifact Reduction Technology of VATECH)
3D SCANNING FOR MODEL

3D model scan enables to store plasters as digital models.

DIGITIZED ONE-STOP CLINIC

* 3D scanning for Plaster Cast with FOV 8x9 (cm)

CAD/CAM INTEGRATION
Sufficient level of detail for surgical guide design
 
SPECIALLY DESIGNED JIG
Stable protection from partial model to full model
*3D scanning for Plaster Cast with FOV 8x9(cm)
 

SPECIFICATION

Green CT 2 : PHT-65LHS
FUNCTION
CT + Pano + Ceph + Model Scan
FOCAL SPOT SIZE
0.5 mm (IEC60336)
CT FOV SIZE
16x9 cm : Multi (5x5 / 8x9 / 12x9 / 16x9 cm) 
18x10 cm : Multi (5x5 / 8x9 / 13x10 / 18x10cm)
VOXEL SIZE
5x5 : 0.08 mm / 0.12 mm
8x9 : 0.12 mm / 0.2 mm
12x9 : 0.2 mm / 0.3 mm
13x10 : 0.2 mm / 0.3 mm
16x9 : 0.2 mm / 0.3 mm
18x10 : 0.2 mm / 0.3 mm
SCAN TIME
PANO 14.1 sec / 7.0 sec
CEPH 3.9 sec / 1.9 sec
CBCT 9.0 sec (12x9 - 18x10) / 4.9 sec (5x5 - 8x9)
GRAY SCALE
14 Bit
TUBE VOLTAGE / CURRENT
60 - 99 kVp / 4 - 16 mA
WEIGHT
Without CEPH unit : 295.4 lbs - without the Base / 412.3 lbs - with the Base
With CEPH unit : 350.5 lbs - without the Base / 467.4 lbs - with the Base
DIMENSIONS
Without CEPH unit : 44.29" (L) x 58.61" (W) x 91.94" (H)
With CEPH unit : 73.78" (L) x 58.61" (W) x 91.94" (H)

* The specifications are subject to change without prior notice.

DIMENSION

 TOP VIEWFRONT VIEW
Without CEPH unit
With CEPH unit

* An additional 3 inches (76.2 mm) of space is required behind the unit for wall mount bracket installation 
(mandatory unless there is a base mount installation).